beautypg.com

Dukane Projector 8107WIB User Manual

Page 10

background image

10

RS-232C Communication (continued)

3. Response code / Error code

("h" shows hexadecimal)

(1) ACK reply : 06h

When the projector receives the Set, Increment, Decrement or Execute

command correctly, the projector changes the setting data for the specified

item by [Type], and it returns the code.

(2) NAK reply : 15h

When the projector cannot understand the received command, the projector

returns the error code.

In such a case, check the sending code and send the same command again.

(3) Error reply : 1Ch + 0000h

When the projector cannot execute the received command for any reasons,

the projector returns the error code.

In such a case, check the sending code and the setting status of the projector.

(4) Data reply : 1Dh + xxxxh

When the projector receives the GET command correctly, the projector returns

the responce code and 2 bytes of data.

NOTE • For connecting the projector to your devices, please read the

manual for each devices, and connect them correctly with suitable cables.

• Operation cannot be guaranteed when the projector receives an undefined

command or data.

• Provide an interval of at least 40ms between the response code and any other

code.

• The projector outputs test data when the power supply is switched ON, and

when the lamp is lit. Ignore this data.

• Commands are not accepted during warm-up.

• When the data length is greater than indicated by the data length code, the

projector ignore the excess data code. Conversely when the data length is

shorter than indicated by the data length code, the projector returns the error

code to the computer.