beautypg.com

Storage, Maintenance, Operation – Desa TB111 User Manual

Page 7

background image

www.desatech.com

119143-01A

7

TO reSTarT heaTer

If safety control stops gas flow to heater, motor
will continue to run.
1. Unplug heater.
. Wait ten seconds. Plug heater in.
If heater does not restart
A. Check supply valves (on propane/LP

tank). Make sure they are open.

B. Check fuel level in propane/LP tank(s). If

fuel level is too low, contact local propane/
LP gas company.

If heater still does not restart, contact your
local service center.

STORAgE

CaUTiOn: disconnect heater

from propane supply tank(s).

1. Store propane/LP tank(s) in safe manner.

See chapter 5 of Standard for Storage and
Handling of Liquefied Petroleum Gases,
ANSI/NFPA 58
and the Natural Gas and
Propane Installation Code CSA B149.1
.
Follow all local codes.

2. Place plastic cover caps over brass fit-

tings on inlet connector of heater and
hose/regulator assembly.

3. Store in dry, clean and safe place. Do

not store hose/regulator assembly inside
heater combustion chamber.

4. When taking heater out of storage, always

check inside of heater. Insects and small
animals may place foreign objects in
heater. Keep inside of heater free from
combustible and foreign objects.

OPERATION

Continued

MAINTENANCE

warninG: never service

heater while it is plugged in,

connected to propane supply,

operating or hot. Severe burns

and electrical shock can occur.

1. Keep heater clean. Clean heater annually

or as needed to remove dust and debris. If
heater is dirty or dusty, clean heater with
a damp cloth.

. Inspect heater before each use. Check

connections for leaks. Apply mixture of
liquid soap and water to connections.
Bubbles forming show a leak. Correct all
leaks at once.

3. Inspect hose/regulator assembly before

each use. If hose is highly worn or cut,
replace.

4. Have heater inspected yearly by a quali-

fied service agency.

5. Keep inside of heater free from combus-

tible and foreign objects.