WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,

paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These

POSSIBLE CAUSE

1. Metal expanding while heating

or contracting while cooling

1. Heater burning vapors from

paint, hair spray, glues, clean-

ers, chemicals, new carpet,

etc. (See IMPORTANT state-

ment above)

2. Gas leak. See Warning

statement above

1. Not enough fresh air is

available

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak. See Warning

statement above

2. Control valve defective

1. Foreign matter between con-

trol valve and burner

2. Gas leak. See Warning

statement above

OBSERVED PROBLEM

Heater produces a clicking/tick-

ing noise just after burner is lit or

shut off

Heater produces unwanted odors

Heater shuts off in use (ODS

operates)

Gas odor even when control knob

is in OFF position

Gas odor during combustion

REMEDY

1. This is common with most heat-

ers. If noise is excessive, contact

qualified service person

1. Open window and ventilate

room. Stop using odor causing

products while heater is running

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 15)

1. Open window and/or door for

ventilation

2. Contact local natural or pro-

pane/LP gas company

3. Clean ODS/pilot (see Cleaning

and Maintenance, page 23)

1. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 15)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 15)

TROUBLESHOOTING

Continued

This manual is related to the following products: