IT IS CRITICAL FOR THE CORRECT OPERATION OF YOUR STOVE THAT THE BURN

GRATE, AIR INLET DAMPER, COMBUSTION FAN SPEED, AND

1 & 4 FUEL RATE BE SET CORRECTLY!

A

HIGH QUALITY FIRE

should burn with a brisk, yellow flame. A flame exhibiting a lazy, orange or sooty

characteristic is a poor quality and inefficient flame. A poor flame produces less heat, increases sooting and may
cause a smoky exhaust. If a poor flame exists for any period of time, clean your stove and exhaust system.

Note: if log option is purchased, do not install until initial setup is complete

START APPLIANCE AS PER LIGHTING INSTRUCTIONS

,

let stove run for approx. 10 minutes before turning the stove to the # 4 setting (or High), to
begin to make fine adjustments

. AUGER CYCLE indicator

should be lit “ON” for 3 seconds

and “OFF” for 3-5 seconds. Adjust the

AIR INLET DAMPER

. This will have to be set, as the

factory sends all units out with the damper wide open to accommodate a wide range of
installations and elevations.

AIR INLET DAMPER

: Slide open or close

damper as needed to obtain a fire that is brisk
enough to carry ash out of the grate, but not so
brisk that it carries pellets out as well (known as
“Pop corning”). Normally you should find that the
damper will need to be closed two-thirds to three
quarters, but will vary with length of vent run, pellet
quality and elevation. The best way to set this is at
the

FUEL SETTING

#4.

When you are pleased with the burn and how the appliance is operating, you
are now ready to set the board up at LOW setting.


Set

FUEL RATE

to

#1 or LOW setting

. Again let this burn for

approx. 10 minutes before making any adjustments. The AUGER
CYCLE indicator should be “OFF” for approx 9 – 14 seconds
between auger turnings (light ON). If “Pop corning” is taking place
at this setting adjust the

COMBUSTION FAN SPEED.

COMBUSTION FAN SPEED (Draft):

In a few instances

because of prevailing conditions pertinent to your specific
installation, or even different batches of pellet fuel, the

COMBUSTION FAN SPEED

may be adjusted to increase or

decrease the amount of air moving through the grate for the
cleanest burn. Fan speed can be adjusted by adjusting the

FAN

trim pod

COUNTER CLOCKWISE to INCREASE

the speed and

CLOCKWISE to DECREASE

the speed of the combustion fan.

FUEL RATE:

Fuel rate at the Lowest (number 1) and highest (number 4) settings can be

changed by adjusting the

#1 or #4 TRIM PODS

located on the control panel. To

INCREASE

fuel rate turn trimmer

COUNTER CLOCKWISE

and to

LOWER

turn

CLOCKWISE

. To assist in knowing what

changes you made, you should note the amount of time the light on the

AUGER CYCLE

stays “OFF”. (Note: The

light stays “off” when ever the fuel feed motor is not running).

Lengthening the time this light stays “OFF”

lowers the fuel feed and shortening the “OFF” time increases the fuel feed. Factory Setting #1 light “OFF”
is approx. 9-11 seconds, #4 light “OFF” is 3-4 seconds.