Operation (cont.) – DENSO CORPORATION OFFICE PRO 24 User Manual
Page 19
13
OPERATION (cont.)
Operating Modes
Both Office Pro models operate in two modes, Fan Only and COOL.
When in Fan Only mode, the unit circulates the surrounding air. When in
COOL mode, the compressor is operational and cool air is circulated.
•
COOL Mode
Both models will operate in Fan Only mode for approximately 90
seconds before the compressor engages. (Time delay setting is 90
± 15 seconds.)
•
Temperature Control
The room temperature thermistor allows the unit to switch automati-
cally between COOL and Fan Only modes. This is dependent upon
inlet air temperature versus SET POINT temperature.
•
Fan Mode Control DIP Switch
The Fan Mode Control DIP Switch determines whether the FAN will
continue to operate or stop when the compressor cycles off. (SET
POINT temperature equals inlet air or room temperature.) The unit
has been preset at the factory for continuous fan operation.
•
Temperature Scale Display DIP Switch
The Temperature Scale Display DIP Switch changes the
temperature(s) that are displayed to either °C or °F. The unit has
been preset from the factory to display the temperature(s) in °F.
NOTE: If you wish to change the fan mode operation
(COOL
OPERATE to COOL
STOP), and/or the Temperature Scale
Display (°F to °C), contact your MovinCool reseller.