beautypg.com

Communications setting, Rs-232c communication, 2 header – Dukane 8062 User Manual

Page 46: 3 command data, Command data chart action (byte_0 - 1)

background image

5

(1) Turn off the projector and computer power supplies and connect with the RS-232C cable.
(2) Turn on the computer power supply and after the computer has started up, turn on the

projector power supply.

Control jack

D-sub 15-pin shrink jack

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

RD

TD

GND

SELO

RTS

1

2

3

4

5

6

7

8

9

CD
RD
TD
DTR
GND
DSR
RTS
DTS
RI

1

2

3

4

5

6

7

8

9

RS-232C jack

D-sub 9-pin

Projector

Computer

Communications setting

19200bps, 8N1

1 Protocol

Consist of header (7 bytes) + command data (6 bytes).

2 Header

BE + EF + 03 + 06 + 00 + CRC_low + CRC_high
CRC_low : Lower byte of CRC flag for command data.
CRC_high : Upper byte of CRC flag for command data.

3 Command data

byte_0

byte_1

byte_2

byte_3

byte_4

byte_5

Action

Type

Setting code

low

high

low

high

low

high

Command data chart

Action (byte_0 - 1)

Action

Classification

Content

1

SET

Change setting to desired value.

2

GET

Read projector internal setup value.

4

INCREMENT

Increment setup value by 1.

5

DECREMENT

Decrement setup value by 1.

6

EXECUTE

Run a command.

RS-232C COMMUNICATION