Installation instructions
For the installer
Safety instructions
-
According to the technical connection
conditions of the electricity board serving
your area, the appliance may only be
connected to the mains supply by an
approved electrical installer.
- in the fixed connection, a device allowing
the appliance to be isolated on all poles
from the mains supply with a contact open
ing width of at least 3 mm must be provid
ed. Suitable isolating devices are Cooker
Control Units.
- In respect of fire protection, the appliance
conforms to type Y (lEC 335-2-6). Only
appliances of this type may be installed
on one side of adjacent upright kitchen
housings or walls.
Access protection must be ensured by
installation.
The distance between the hob and vapour
extractor hood must be of the extent indi
cated in the instaliation instructions of the
vapour extractor hood.
Electricai connection of appiiance
Local and national electrical regulations must
be observed.
All instructions given by the Electricity Board
must be followed carefully when connecting
the oven to the mains supply.
The appliance Is rated for 240 volts single
phase and must be permanently connected.
The hob must be installed in such a way that it
can be easily disconnected from the mains
supply before servicing, eg by an adjacent
cooker control unit.
Sufficient cable should be left to enable the
hob to be removed from the work surface
whilst still connected to the mains supply
(approximately 1.5 metres or 5 ft).
When pushing the hob into the cutout of the
furniture housing, make sure that the mains
cable is neither kinked nor trapped under the
appliance.
Warning - This appliance must be earthed!
Voitage and Current
Please ensure that the voltage and current
indicated on the rating plate agrees with the
voltage of your electricity supply.
220/240 volts (ie 220/240 V a.c.).
After installation there must be no access to
live parts.
11