DRIVE TYPES
L —Multi-speed direct drive heating—minimum cooling.
E—Multi-speed direct drive heating —maximum cooling
with evaporator motor relay.
COMPONENT INFORMATION
Motor - Type L - 4 Speed
1/8 HP (Sh. Pole)
Power Supply
120-60-1
Full Load Amps
6.3
Speed & Rotation
1050 CCW*
Motor - Type E - 4 Speed
1/3 HP (PSC)
Power Supply
120-60-1
Full Load Amps
6.5
Speed & Rotation
1075 CCW*
Blower Wheel Dia. & Width
10
X
8
Bore - Direct Drive
1/2"
Filter - Fiber Glass**
Inlet at Bottom
16
X
25
X
1"
External Filter Rack
P/N 60559D0I
16
X
25
X
1"
Internal Side Filter Rack
16
X
25
X
1"
Rear Drop Duct P/N 60569D02
16
X
25
X
1"
Bottom Enclosure
P/N 56201C07
* Rotation viewed from end opposite shaft
**Use multi-velocity filters above 1000 CFM
CONNECTIONS
Gas Supply NPT - Natural
1/2
- Propane
1/2
Electric Supply - Direct Drive
120-60-1
Branch Circuit Wire Size
AWG
14
Fuse Size
Amps
15
Control Circuit Power Available*
Type L
VA
10.8
Type E
VA
7.2
Flue Size
Inches
5 (Oval)
Duct - Inlet at Bottom
D&W
22-1/4
X
14-1/4
Inlet Ext. Filter Rack
H&W
14
X
23
Inlet Drop Duct
D&W
12
X
16-5/8
Discharge
H&W
20
X
16-5/8
AIRFLOW FOR INDICATED AIR TEMPERATURE RISE^
TEMP RISE °F
70
75
80
85
90
95
100
AIRFLOW CFM
993
926
869
818
772
732
695
*At Rated Input
PDS 394U.100.5