Atwood Mobile Products 1H2C User Manual
Atwood, Hydro flame
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
/
9
<
Atwood'
Atwood Mobile Products
llx
:
1120
North Main Street • Elkhart, IN
46514
PHONE:
574-264-2131
FAX;
574-262-25
50
INTERNET:
LITERATURE NUMBER
MPD 31492
hydro flame™
Model1H2C
Digital Thermostat
FOR STANDARD FURNACES
& A/C SYSTEMS
ENGLISH, FRANÇAIS
(et Canada)
«Installation «Operation
Effective 9/21/04
THIS THERMOSTAT HAS BEEN DESIGNED TD DPERATE STANDARD AIR CONDITIDNING UNITS IN CONJUNCTION WITH A RV FURNACE.
SPECIFICATIONS
Operating Voltage............................... 9VDC to 18VDC
Current Consumption at 12V0C ........................ 100mA
Operating Temp.....................................-40F to +185F
Room Temp. Range ................................+55F to +90F
Room Temp. Display Range .................... +35F to +99F
Thermostat Accuracy.......................................... t/- 1F
Switching Capability A/C............................up to 24 VAC
uispiay Kioaesei
(max. 2 AMPs)
•Note: Move jumper to
positions 3 and 4 for RVP
Unit. Discard jumper for
Dometic”.
SLIDE SWITCH
LEFT RIGHT
SCROLL ORDER OF
DISPLAYED MODES
OPERATION
COOL OFF HEAT FAN
Furnace Operation
•
HI
Furnace cycles to satisfy set point.
COOL OFF HEAT FAN
Air Conditioner Operation
•
AU
Air conditioner automatically switches compressor and high and
low speed fan when cycling to satisfy set point.
•
HI
Air conditioner compressor and high speed fan cycle to satisfy
set point.
•
LO
Air conditioner compressor and low speed fan cycle to satisfy
set point.
COOL OFF
HEAT FAN
Fan Operation
•
HI
Air conditioner fan runs at high speed to circulate air.
•
LO
Air conditioner fan runs at low speed to circulate air.
COOL OFF HEAT FAN
Off
•
OF
No operation occurs.
PMtSW MM
THERMOSTAT INSTALLATION
Thermostat js very sensitive,
handle
WITH CARE AT ALL TIMES.
Locate thermostat 48” to 54" above
floor on an
INTERIOR
Wall. Pick a dry
area where air circulation is good.
EXTERIOR
wall location must have a
3/4" spacer between thermostat and
exterior wall.
1. Be sure all electrical power has
been disconnected from the air
conditioner, furnace and the
power supply.
2. Do not install the thermostat
where there are unusual heating
conditions: such as direct
sunlight, heat producing
appliances (television, radio, wall
lamp, etc.) or a furnace or air
conditioner supply register.
3.
AHACHING THE WALL THERMOSTAT.
Separate the thermostat body
from the sub-base by gently
squeezing the top and bottom,
connecting wiring per
requirements. Attach thermostat
sub-base to the wall at desired
mounting location.
WIRING REQUIREMENTS FOR ATWOOD THERMOSTAT