Low-voltage wiring, Limit control, Thermostat location – Bryant 394 Gas User Manual
Page 4: Iii. electrical connections, Line-voltage wiring
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

I
TO HEATING AND
COOLING CONNECTIONS
OF THERMOSTAT
P/N 34427D030
a 34427D031
\ TO CONDENSER
> CONTACTOR COIL
I
CONNECTIONS
A68367
Figure 2 - Control Box, Cover Removed,
No Internal Wiring Changes
TO HEATING AND
COOLING CONNECTIONS
VOF THERMOSTAT
^P/n 34427D030
a 34427D031
] TO CONDENSER
I LOW VOLTAGE
(^LEAD OR
j TERMINAL STRIP
NOTE-'
WIRE WITH* IN FIGURE 2 IS
REMOVED, AND DISCARDED WHEN
A68368 CONDENSEFTHAS TRANSFORMER.
Figures 3 - Control Box, Cover Removed,
Showing Internal Wiring Changes
Low-Voltage Wiring
Field low-voltage connections are made at the low-
l^oltage terminal strip. See Figure 6 for heating only.
For Model
394
Furnaces used in conjunction with
slectric or gas air conditioning units that do not have
4n integral transformer, see Figure
2.
If the
394
Fur-
fiace is used in conjunction with an electric or gas air
jonditioning unit having an integral transformer, see
Figure
3.
Figure
3
shows a field-installed wire running from one
side of the air conditioning transformer, through the
4ole marked “F” in the terminal strip to the blower
relay in the control box for the Model
394
Furnace.
The wire marked * in Figure
2
is removed from the
:ontrol box and discarded.
Limit Control
This control shuts oflF the gas and energizes the blower
notor if the furnace becomes overheated.
The recommended method of checking the limit control
s to gradually block off the return air after the furnace
,ias been operating for a period of at least five minutes.
\s soon as the limit has proven safe, the return air
opening would be unblocked to permit normal air
jirculation. By using this method to check the limit
control, it can be established that the limit is function-
ng properly and will “fail-safe” if there is a motor
ailure.
Thermostat Location
The room thermostat should be located where it will
re in the natural circulating path of room air. Avoid
locations where the thermostat would be exposed to
cold air infiltration, drafts from windows, doors, or
other openings leading to the outside, or exposure to
air currents from warm or cold air registers; or to ex
posure where the natural circulation of the air is cut
off—such as behind doors, above or below mantels,
shelves, etc.
The thermostat should not be exposed to heat from
nearby radiators, fireplaces, radios, televisions, lamps,
or rays from the sun. Nor should the thermostat be
mounted on a wall containing pipes or warm air ducts,
or a flue or vent which could affect its operation and
prevent it from properly controlling the room tempera
ture. Any hole in the plaster or panel through which
the wires pass from the thermostat should be adequately
sealed with suitable material to prevent drafts from
affecting the thermostat.
The heat anticipator on the thermostat should be set
at 0.8 amps.
III. ELECTRICAL CONNECTIONS
Line-Voltage Wiring
All electrical connections are to be made in accordance
with the local electrical codes. A permanent, live,
separately fused electric power supply, complete with
manual switch, should be provided for the furnace.
Field wiring connections should be made in accordance
with the unit wiring diagrams.
-
4
-