beautypg.com

Ariston FR 34 S GB User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Electrical connection

Ovens with a three-pole power supply cable are designed

to operate with alternated current at the supply frequency

and voltage indicated on the data plate (at the bottom of

the oven dashboard).The earthing conductor of the cable

is the yellow-green conductor.

Two types of connection are provided:

Connection n° 1
Connecting the power supply cable to the mains.

Fit a normalized plug to the cable, which corresponds to

the load indicated on the data plate; if the cooker is

connected directly to the mains, an omnipolar circuit-
breaker with a minimum opening of 3 mm between the
contacts, suitable for the load indicated and complying
with current directives, must be installed between the

appliance and the mains (the earthing wire must not be

interrupted by the circuit-breaker). The power supply cable
must be positioned so that it does not exceed room tem­

perature by 50°C at any point of its length. Before making

the connection check that:

the circuit breakers or fuses of the home system can

support appliance load (see data plate);

the power supply system has an efficient earthing

connection which complies with the provisions of
current regulations and the law;

there is easy access to the socket or the omnipolar

circuit-breaker once the cooker has been installed.

N.B.: do not use reducers, adapters or shunts as these

could cause heating or burning.

Connection n° 2

Disposing of the plug.

WARNING:THIS APPLIANCE MUST BE EARTHED.

Ensure that before disposing of the plug itself, you make

the pins unusable so that it cannot be accidentally inserted

into a socket. Instructions for connecting cable to an alter­
native plug:
important: the wires in the mains lead are coloured in
accordance with the following code:

Green & Yellow

-Earth

Blue

-Neutral

Brown

-Live

If the colours of the wires in the mains lead do not

correspond with the coloured markings identifying the
terminals in your plug, proceed as follows.

Connect Green &Yellow wire to terminal marked “E”or^
or coloured Green or Green & Yellow.

Connect Brown wire to terminal marked “L” or coloured

Red. Connect Blue wire to terminal marked “N” or coloured

Black. If a 13 amp plug (BS 1363) is used it must be fitted
with a 13 amp fuse.
A15 amp plug must be protected by a 15 amp fuse, either

in the plug or adaptor or at the distribution board.If you

are in any doubt about the electrical supply to your

machine, consult a qualified electrician before use.

How to connect an alternative plug

The wires in this mains lead are coloured in accordance
with the following code:

BLUE

“NEUTRAL” (N)

BROWN

“LIVE” (L)

GREEN AND YELLOW

“EARTH” (E)

Disposing of the appliance

When disposing of the appliance please remove the plug

by cutting the mains cable as close as possible to the
plug body and dispose of it as described above.

The plug and socket must be easily accessible.

10