American Standard Hampton 7225.713 User Manual
Hampton, Amtiea*! sfcmhud, Installation instructions
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
AMtiea*! Sfcmhud
HAMPTOn
THREE HANDLE BATH/SHOWER SET
WITH TRANSFER VALVE
Installation
Instructions
7225.703
7225.713
7225.723
7225.733
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-
please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
U S. Patent No. 5,819,789
US60407 REV. 1.1
ROUGHING-IN DIMENSIONS
NOTE: NO CONCEALED PIPING FURNISHED
1-1/4 DIA HOLE--------- 1
1/2"N.RT.
SHOWER ARM
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65” AND 78”
FINISHED
WALL
1/2" N.RT TO
SHOWER
CROSS
BRACE
(2) 1-13/16" DIA. HOLES
FOR VALVES ON 8"
CENTERS (1] 1-13/16"
DIA. HOLE FOR CENTER
TRANSFER VALVE
1B OPTIONAL
BOTTOM OF TUB
Required Tools
Flat Blade Screwdriver
Phillips Screwdriver
Plumbers' Putty or Caulking
I
Channel Locks
*Hex key Supplied with Fitting
ROUGHING-IN
SHOWER AND SPOUT
CAUTION
IVrn off hot and cold water
supplias bsfors beginning.
"SHR" is pointing upward. Mount VALVE (11 to cross brace with wood screws.
Slip COUPLING NUT over supply pipe and thread UNION SWIVEL to pipe.
Connect HOT (6) water supply to LEFT valve inlet and COLD (71 water supply
IMPORTANT: DO NOT REMOVE PLASTER GUARDS (2J UNTIL STEP 2.
Prepare water supplies per Roughing-in Dimensions. Apply sealing tape
to all threaded connections.
Install VALVE (11 at indicated height and depth. Make sure the outlet marked
------------------- ■ ■■ itVA--------------------------------
Slip COUPLING NUT over supply pipe and thread UNION SWIVEL to pipe.
■ ” ■ '
ply to I "
to RIGHT valve inlet.
Prepare SHOWER RISER (41 and ELBOW (31. Connect to TOP outlet, marked
"SHR" of VALVE BODY (11.
Prepare TUB FILLER PIPE (8], ELBOW (101 and roughing-in NIPPLE (91.
Connect to BOTTOM outlet of VALVE BODY (11.
Add cross braces to wall structure and secure piping.
Cap NIPPLES (9 & 51 and open supply lines and check for leaks. Remove
PLASTER GUARDS (21. Use spline on end of PLASTER GUARD (21 to open
both VALVES and check for leaks. Operate transfer valve and check for leaks.
Close both valves and turn off water supplies. Replace PLASTER GUARDS (21.
Finish wall construction.
'ODD SCREWS
CROSS
BRACE
-COUPLING
NUT