beautypg.com

En replacement of the demineralization cartridge, Option a: replace the resin, Option b: replace the whole cartridge – Air-O-Swiss AOS 7135 User Manual

Page 14

background image

14

en

Replacement of the demineralization

cartridge

Always unplug the unit before removing the

water tank. Do not touch the water in the base

during operation!

The water tank is equipped with a demineralization cartridge.

This cartridge has to be replaced every 2 – 3 months. If

the water is very hard, it may be necessary to replace the

cartridge earlier. White dust around the device is a sure sign

that the cartridge needs replacing. Please note white dust

is not harmful. If white residue still forms around the device

after a new cartridge has been inserted, please make sure

that the water you are using is untreated. If the water flows

through a decalcification system – such as an ion exchanger

– (sodium is added to remove calcium) in the building before

it is used in the humidifier, salt can precipitate as white dust

around the device. The demineralization cartridge and or the

granules must be exchanged at the latest after 6 months or

the unit does not reach its full performance anymore.

Option A: replace the resin

• Remove the water tank from the base and unscrew the

water tank cap (29). Caution: the mist outlet is loose!

• The demineralization cartridge is attached to the tank

cap. Unscrew the cartridge from the cap by turning it

counter­clockwise (30). Important: do NOT dispose of

the water tank cap!

• Open the cartridge (31).

• Throw the content into the waste (Attention! Disposed

resin can make the floor slippery!) (32).

• Place the enclosed pink styrofoam piece in the center

of the cartridge. Do not push it to the bottom as it will

be difficult to remove afterwards (33).

• Pour the contents of one refill resin bag into the plastic

cup that is included with the refill resin packaging (34).

• Place the empty cartridge with the plug in the center

onto the plastic cup (35).

• Turn the plastic cup and cartridge over and shake until

all resin is in the cartridge (36).

29

30

31

32

• Remove the plastic cup and the pink styrofoam piece

from the cartridge (37) and retain for future use (the

refill resin consists of 3 refill bags) (38).

• Close the cartridge (39).

• Soak the demineralization cartridge in a water bath

24 hours before using it (42). The resin has to absorb

water to reach maximum performance. If it is soaked in

the tank, make sure to exchange the water and empty

the water from the base before using the humidifier.

• Screw the cartridge on the water tank cap (43).

• Screw the cartridge on the bottom side of the water

tank, put the tank on the main body (44).

Placing granules in the center of the cartridge

allows them to escape in the unit or to clog the

unit. The unit will no longer operate properly and

the granules need to be cleaned out thoroughly.

Option B: replace the whole cartridge

• Remove the water tank from the base and unscrew the

water tank cap (29). Caution: the mist outlet is loose!

• The demineralization cartridge is attached to the tank

cap. Unscrew the cartridge from the cap by turning it

counter­clockwise (30). Important: do NOT dispose of

the water tank cap!

• Throw the whole cartridge into the waste (40).

• Unpack the new cartridge (41).

• Soak the demineralization cartridge in a water bath

24 hours before using it (42). The resin has to absorb

water to reach maximum performance. If it is soaked in

the tank, make sure to exchange the water and empty

the water from the base before using the humidifier.

• Screw the cartridge on the water tank cap (43). Close

tank cap well and place the tank on the main body

(44).