OPERATION
Before you begin using your thermostat, you should be familiar
with its features and with the display and the location and
operation of the thermostat buttons. Your thermostat consists of
two parts: the thermostat cover and the base. To remove the
cover, pull it straight out from the base. To replace the cover, line
up the cover with the base and press until the cover snaps onto
the base.
The Thermostat Buttons and Switches
(see fig. 8)
© Raises temperature setting.
Lowers temperature setting.
0 FAN switch
(ON, AUTO).
0 SYSTEM switch
(COOL, OFF, HEAT).
The Display
(0
Flame icon (¿))
is displayed when the SYSTEM switch
IS in
the HEAT position. Snowflake icon (*)is displayed (non
flashing) when the SYSTEM switch is in the COOL posi
tion. Snowflake is displayed (flashing) if the thermostat is
in lockout mode to prevent the compressor from cycling
too quickly.
(0 Displays current temperature.
(0
Displays "FILTER" when the system has run for the se
lected filter time period as a reminder to change or clean
your air filter.
(0
Displays set point temperature (this is blank when SYS
TEM switch is in the OFF position).
(0
Displays "BATTERY" and "LO" in the current temperature
location when the 2 "AA" batteries are low and should be
replaced.
F
r n
~ i n c n n
l U и и
l U u u
BATTERY i Ò
FILTER t *
8 ) ( 5
7 )
( 6
Figure 8. Thermostat display, buttons, and switches
CONFIGURATION MENU
The configuration menu allows you to set certain thermostat
operating characteristics to your system or personal require
ments.
Move SYSTEM switch to the OFF position, then press and
at the same time to enter the configuration menu. The
display will show the first item in the configuration menu.
The configuration menu chart below summarizes the configura
tion options. An explanation of each option follows.
Press and to change to the next menu item. To exit the
menu, move the SYSTEM switch to HEAT or COOL. If no keys
are pressed within fifteen minutes, the thermostat will exit the
configuration menu.
Configuration Menu
Step
Press
Button(s)
Displayed (Factory Default)
Press © or © to select:
COMMENTS
1
Set SYSTEM
switch to OFF
SYSTEM switch must be OFF to configure thermostat
options
2
0>andQ
Ф
(FA)
SL
Select FA or SL (Fast or Slow) heating cycle rate
3
©and©
d-L
(ON)
OFF
Select display backlight OFF or ON
4
©and©
FILTER
(000)
0 to 1950 hours
(in 50 hour increments)
Select Filter replacement run time
5
©and©
LOG
(OFF)
ON
Select Compressor lockout OFF or ON
6
©and©
0 HI
(0)
4 LOto
4 HI
Select temperature display adjustment higher or lower
7
©and©
(F)
C
Select temperature display to F or C
8
Set SYSTEM
switch to HEAT
or COOL
Returns to normal operation
' Press Q and Q to advance to next item