beautypg.com

Intended uses, Restricted uses, Specifications – Winco HPS12000HE/A User Manual

Page 4

background image

8199-00

Page 2

60707-117

MODEL

HPS12000HE

Generator
Surge Watts*

12000

Continuous Watts*

10800

Volts 120/240
AMPs @ 240 Volts

45.0

AMPs @ 120 Volts

90.0

* Derate 10% for LP and 20% for NG

Engine

Honda

Size

20 HP

Model

GX620K1VXE2

Type -

See Engine Shroud For Type

Fuel Capacity-

15 gal

Fuel Consumption

Gasoline

1.67 gal/hr

LP

2.2 gal/hr

NG

200 cu ft/hr

Starting System

12V Electric

Stop System

Key

Complete Unit
Weight (dry)

274 LBS

Dimensions LxWxH

32 X 22 X 22

Fuel

Gasoline/LP/NG

Oil Type

SG SF/CC CD

Oil Weight (for general use)

10W -30

See engine manual for additional information
Oil Capacity

1.3 Quarts

Battery 12 Volt

Group U1/235CCA

INTENDED USES

These engine generator sets have been designed primarily
for portable use. Both 120 and 240 Volt AC receptacles are
provided in the 'control panel' to plug in your loads (lights,
portable tools, and small appliances). These units are dual
wound generators, therefore the 120 Volt loads must be
equally split with 1/2 of the rated capacity available on each
of the two 120 Volt circuits. See unit capabilities for further
explanation.

These portable units require large quantities of fresh air for
cooling of both the engine and the generator. Fresh air is
drawn from both the engine end and the generator end and is
exhausted at the center of the unit. For safety, long life and
adequate performance, these units should never be run in
small compartments or enclosed areas without positive fresh
air flow.

RESTRICTED USES

DO NOT remove from the cradle assembly. Removal of the
generator from the cradle assembly may cause excessive
vibration and damage to the engine generator set.

DO NOT install and operate these portable generators in a
small compartment., i.e. generator compartment of vehicles,
motor homes or travel trailers. These compartments will not
allow enough free flow fresh air to reach the engine
generator set for cooling and will cause the unit to overheat,
damaging both the engine and the generator. Small
compartments will also develop hot spots where there is very
little air flow and may cause a fire.

DO NOT attempt to operate at 50 cycles. These units are
designed and governed to operate at 60 Cycles only.

SPECIFICATIONS

MODEL

CSAHPS6000HE

Generator
Surge Watts*

6000

Continuous Watts*

5500

Volts

120/240

AMPs @ 240 Volts

22.9

AMPs @ 120 Volts

45.8

* Derate 10% for LP and 20% for NG

Engine

Honda

Size

11 HP

Model

GX340K1WE2

Type -

See Engine Shroud For Type

Fuel Capacity-

4.5 gal

Fuel Consumption

Gasoline

1.0 gal/hr

LP

1.6 gal/hr

NG

160 cu ft/hr

Starting System

Recoil/12V Electric

Stop System

Key

Complete Unit
Weight (dry)

212 LBS

Dimensions LxWxH

30 X 22 X 22

Owner Must Provide
Fuel

Gasoline/LP/NG

Oil Type

SG SF/CC CD

Oil Weight (for general use)

10W -30

See engine manual for additional information
Oil Capacity

1.2 Quarts

Battery 12 Volt

U1/235CCA

MODEL

CSAHPS9000E

Generator
Surge Watts*

9000

Continuous Watts*

8000

Volts 120/240
AMPs @ 240 Volts

33.3

AMPs @ 120 Volts

66.7

* Derate 10% for LP and 20% for NG

Engine

Briggs & Stratton

Size

16 HP

Model

303447

Type -

See Engine Shroud For Type

Fuel Capacity-

4.5 gal

Fuel Consumption

Gasoline

1.3 gal/hr

LP

1.9 gal/hr

NG

180 cu ft/hr

Starting System

Recoil/12V Electric

Stop System

Key

Complete Unit
Weight (dry)

274 LBS

Dimensions LxWxH

32 X 22 X 22

Fuel

Gasoline/LP/NG

Oil Type

SE SG SF

Oil Weight

See Engine Manual

specific information

Oil Capacity

1.75 Quarts

Battery 12 Volt

U1/235CCA

This manual is related to the following products: