Wiring diagram, Troubleshooting hints – Winco WC10000VE User Manual
Page 11
11
1219-00
60706-222
gerous to the operator and destructive to the
equipment.
CLEANING
Remove dirt and debris with a cloth or brush. DO
NOT use high pressure spray to clean either the
engine or the generator. This high pressure spray
could contaminate the fuel system and the generator
components.
1. Keep the air inlet screen on both the engine and
generator free of any dirt or debris to insure proper
cooling. At least yearly remove the blower housing
on the engine and clean the chaff and dirt out of the
engine cooling fi ns and fl ywheel. Clean more often
if necessary. Failure to keep these areas clean may
cause overheating and permanent damage to the
unit.
2. Periodically clean muffl er area to remove all
grass, dirt and combustible debris to prevent a fi re.
3. On engine muffl ers equipped with spark arrest-
ers, the spark arrester must be removed every 50
hours for cleaning and inspection. Replace if dam-
aged.
WIRING DIAGRAM
TROUBLESHOOTING HINTS
PROBLEM (SYMPTOMS) POSSIBLE
CAUSES
———————————————————————
Won’t Start
*Low Oil Level.
*Fouled
spark
plug.
*Out
of
fuel.
*Start switch in Off position.
———————————————————————
Voltage too low
*Engine speed is too low.
*Generator
overloaded.
*Defective
stator.
*Defective
rotor
(fi eld).
———————————————————————
Circuit Breaker
*Defective load.
Trips
*Defective
receptacle.
———————————————————————
Voltage too high
*Engine speed is too high.
———————————————————————
Generator
*Overloaded.
overheating
*Insuffi cient ventilation.
———————————————————————
No output voltage
*Short in load (disconnect).
*Broken or loose wire.
*Defective
receptacle.
*No
residual
magnetism
(in
generator).
*Defective
stator.
*Defective
rotor
(fi eld).
*Shorted
capacitor.
*GFCI
Receptacle
tripped.
———————————————————————