beautypg.com

Wiring diagram, Troubleshooting hints – Winco WC10000VE User Manual

Page 11

background image

11

1219-00

60706-222

gerous to the operator and destructive to the
equipment.

CLEANING

Remove dirt and debris with a cloth or brush. DO
NOT use high pressure spray to clean either the
engine or the generator. This high pressure spray
could contaminate the fuel system and the generator
components.
1. Keep the air inlet screen on both the engine and
generator free of any dirt or debris to insure proper
cooling. At least yearly remove the blower housing
on the engine and clean the chaff and dirt out of the
engine cooling fi ns and fl ywheel. Clean more often
if necessary. Failure to keep these areas clean may
cause overheating and permanent damage to the
unit.

2. Periodically clean muffl er area to remove all
grass, dirt and combustible debris to prevent a fi re.

3. On engine muffl ers equipped with spark arrest-
ers, the spark arrester must be removed every 50
hours for cleaning and inspection. Replace if dam-
aged.

WIRING DIAGRAM

TROUBLESHOOTING HINTS

PROBLEM (SYMPTOMS) POSSIBLE

CAUSES

———————————————————————
Won’t Start

*Low Oil Level.

*Fouled

spark

plug.

*Out

of

fuel.

*Start switch in Off position.

———————————————————————
Voltage too low

*Engine speed is too low.

*Generator

overloaded.

*Defective

stator.

*Defective

rotor

(fi eld).

———————————————————————
Circuit Breaker

*Defective load.

Trips

*Defective

receptacle.

———————————————————————
Voltage too high

*Engine speed is too high.

———————————————————————
Generator

*Overloaded.

overheating

*Insuffi cient ventilation.

———————————————————————
No output voltage

*Short in load (disconnect).

*Broken or loose wire.

*Defective

receptacle.

*No

residual

magnetism

(in

generator).

*Defective

stator.

*Defective

rotor

(fi eld).

*Shorted

capacitor.

*GFCI

Receptacle

tripped.

———————————————————————