TYREDOG TD-1000A-X Owners Manual User Manual
Page 22

21
Sleep Mode
The Tyredog monitor has a built in vibration sensor which is used to save
power. If the unit is left still for 15 minutes, it will automatically turn off.
If the monitor receives any vibration or a button is pressed, it will
automatically power up to its previous state. This is handy if the monitor is
being used on battery power, or is wired to a permanent 12 volt source.
Once the system is in learning mode, you can proceed to program your new
learnable sensors. Simply insert the battery into the learnable sensor to
activate its code in the monitor’s memory. When the code is learnt, the
monitor will beep once, and the new code will be displayed in the
corresponding wheel location on the display.
If a battery is inserted to a non learnable original sensor, the monitor will beep
3 times to indicate that is not a learnable code. If you hear 3 beeps with your
learnable sensor, please contact your reseller.