background image

Page 3-1

3.0

CONNECTING THE DIGITAL INDICATOR TO THE PLATFORM


The TSM5-28-LS Scale is generally purchased with the TS-700 SS digital indicator. This section
covers connecting the TS-700 SS digital indicator with the Alleyway weighing platform.

The scale interface cable is pre-wired to the TS-700 SS digital indicator.


STEP 1: Access the junction box by removing the screws that secure the access plate on the
side of the Alleyway weighing platform.

3.1

Connecting the TS-700 SS Digital Indicator

1. Locate the interface cable in the carton with the indicator. The cable will be

prewired to the indicator.

2. Remove junction box access panel screws and slide out the junction box tray.

3. Feed the interface cable from the digital indicator through the watertight fitting

on the side of the junction box. If necessary, loosen the fitting nut to increase
the size of the hole.


4. Connect the wires to the terminals on the circuit board using the color codes

in the table below.

Color

Terminal

Red

Exc +

Black

Exc -

Green

Sig +

White

Sig -

Bare

Shld