3 weighing specifications, 4 communication specifications, Eighing – Sterling Scale XC880A User Manual
Page 49: Pecifications, Ommunication

XC880A OWNERS MANUAL
8.3 Weighing Specifications
Capacity Range:
2Lbs (1Kg) to 500,000 Lbs (250,000 Kgs)
Input Range:
0.5mV/V to 3mV/V.
Internal Counts:
10,000,000(Nom.) 16,777,215(Max.)
Display Counts:
Up to 100,000 / 10,000 recommended for stability.
Input Sensitivity:
2
µ
V per display graduation (using 2mV/V input @
10,000 display counts)
Formula: Sensitivity = ((mV/V*excitation voltage)/
Display counts)
Linearity:
.01% of full-scale capacity.
Overload:
105% of full-scale capacity.
Load Cell Excitations:(Standard): 10VDC @ .5A max.
(Up to 9-350
Ω
load cells).
Load Cell Excitation: (Optional): 10VDC @ 1.5A max.
(Up to 27-350
Ω
load cells).
Calibration:
2-step keyboard digital, or direct coefficient
entry.
8.4 Communication Specifications
Ports:
Three RS-232 Full Duplex/Individually
Configurable. Optional RS485 or 10 BaseT
Ethernet on COM1.
Baud Rate:
Port Selectable: 1200 – 115200 bps.
Up to 10Mbps on Ethernet.
Start/Stop Bits:
Fixed at 1 for all ports.
Parity:
Port selectable: Even, Odd, or None.
Word Size:
Port selectable: 7 or 8 bits.
Flow Control:
None.
46