beautypg.com

Solberg BBFS(Pg.2-8) User Manual

Page 6

background image



Solberg Manufacturing, Inc., 1151 Ardmore Itasca, IL 60143 USA

Ph: 630.773.1363 Fax: 630.773.0727 Email: [email protected] Web: www.solbergmfg.com

Page 6

Rule of Thumb

#

4: Pressure drop is also caused by the dirt holding capacity of

the element. As the element fills up with dirt, the pressure drop increases. It is
important to document the pressure drop across a given filter when it is new and
then clean or replace it when the pressure drop increases b

y 10” to 15” / 250-

280mm H

2

O over the original reading.


Rule of Thumb #5:
The inlet connection greatly influences the overall pressure
drop of the filter system. To minimize the restriction contributed by an inlet filter, a
velocity of 6,000 ft

3

/min (10200m

3

/h) or less is suggested through the outlet pipe.

The table below lists the suggested flows based on pipe size:

Pipe Size

(inches)

Max Airflow

6”

1,100 CFM 1870m

3

/h

8"

1,800 CFM 3060m

3

/h

10"

3,300 CFM 5610m

3

/h

12"

4,700 CFM 7990m

3

/h

14"

6,000 CFM 10200m

3

/h

Table 3

*Note: This information is for general use only. A qualified engineer must properly design each system.



3. Element Specifications

Temperature Range: -15° to 220°F / -26° to 105°C
Filter Change-

Out Differential: 10” to 15” / 250-380mm H

2

O Over Initial Delta P

Media

Micron Rating

Standard Paper

99+% @ 2 micron

Standard Polyester

99+% @ 5 micron

“S” Series Wire Mesh

Epoxy Coated Wire Mesh

“Z” Series Polyester

99+% @ 1 micron

“HE” Series HEPA

99.97% @ 0.3 microns

“U” Series Polyester

99+% @ 25 micron

“W” Series Polyester

99+% @ 100 micron

“S2” Series

Stainless Steel Wire Mesh

“AC” & “ACP” Series

N/A

“Y” Series Polypropylene

99+% @ 5 micron

Table 4

Temperature Range: -15° to 385°F / -26° to 196°C
Filter Change-Out Differential:

10” to 15”/ 250-380mm H

2

O Over Initial Delta P

Media

Micron Rating

“MX” & “MXD” Series – Nomex Cloth

99+% @ 5 micron

Table 5