INSTALLATION INSTRUCTIONS

PAGE 02

Rough installation

- Turn the water supplies off.

- Remove all the trim items (plate and handle) before

installation.

- Secure the valve firmly against the stub.

- Make sure that the shower out let is in the up position.

- Flush or raise grouting on the tiled wall surface.

- Connect the supply lines to the valve inlets.

- The rough de pth must fall within the minimum/

maximum

range lines marked on the plas ter guard.

- For both functional and esthetic reasons, the valve must

be leveled horizontally.

- When soldering the inlet connection, make sure that all

internal parts are removed to avoid damages to the non-

metal parts.

- If only the shower portion of the valve will be used, keep

the tub outlet plugged at all time.

-

M

a

x

M

in

Finished wall

Minimum and

Maximum Lines

Trim installation

M

ax

M

in

1.

- Remove the screws from the plaster

guard.

- Remove the plaster guard.

Thermostatic control