INSTALLATION INSTRUCTIONS

7093TD _ _

PAGE 02

Rough installation

- Turn the water supplies off.
- Remove all the trim items (plate and handle) before
installation.
- Secure the valve firmly against the stub.
- Make sure that the shower out let is in the up position.
- Flush or raise grouting on the tiled wall surface.
- Connect the supply lines to the valve inlets.
-

The rough depth

must fall within the minimum/

maximum

range lines marked

on the plaster guard.

- For both functional and esthetic reasons, the valve must
be leveled horizontally.

- When soldering the inlet connection, make sure that all
internal parts are removed to avoid damages to the non-
metal parts.

- If only the shower portion of the valve will be used, keep
the tub outlet plugged at all time.

-

M

a

x

M

in

Finished wall

Minimum and
Maximum Lines

Trim installation

M

a

x

M

in

1.

- Remove the screws from the plaster
guard.
- Remove the plaster guard.