INSTALLATION INSTRUCTIONS
FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION
.
AFTER FLUSHING , SHUT OFF BOTH SUPPLY LINES.
MINIMUM HOLE SIZE FOR THE SPOUT AND HANDLE TRIM IS 1
1/4
” AND MAXIMUM OF 1
1/2
”
SPOUT INSTALLATION
1
- Put the complete bridge assembly (1) aligning two holes on the top of the sink.
Apply a ring of silicon caulking around the center hole on the top of the sink. Do not use
plumbers' putty which can damage the finish of the faucet.
- From the top of the deck, insert the spout's threaded shanks through two holes of the sink,
which are 8” apart. Make sure the spout flange washer (2) is properly placed under-
neath the flange and snugly pressed against the sink top.
2
- Slip the metal washer (3) back onto the shank. First the rubber washer, then the metal
washer and lastly the brass lock nut. Tighten the lock nut firmly.
- Put the O-ring (8) on the top of the lift rod shank. Place the lift rod flange (8) from the
top of the deck, under the bridge at the center hole. Thread flange in to the
lift rod flange (7). Place rubber washer (9), crimped metal washer (10) and lift rod
lock nut on the lft rod shank. Firmly tighten the lift rod lock nut.
Insert the lift rod through the concentric hole of the lift rod shank upwards to the top of the deck.
Screw the popup lift rod in to the hole in the lift rod.
- Make sure the lift rod operates smoothly. Adjust it if necessary.
- Tighten to seal.
- Align the spout and tighten the shank lock nuts firmly.
HOSE TRIM INSTALLATION
1
- Two inlet and outlet hose are given to connect the hot and cold water inlets.
Put on the hose on the thread shank of the bridge. Screw on the nuts of the
hose upwards on the shank.
- Connect other end of the hose to the supply lines of the water to cold and
hot water lines respectively.
- Tighten the nuts until it secures the shank body firmly.
PAGE 02