Installation instructions, Hand held shower trim installation, Water test and flush the line – Santec 3156ML-TM User Manual
Page 3

INSTALLATION INSTRUCTIONS
PAGE 03
HOT WATER
SUPPLY
COLD WATER
SUPPLY
From Diverter
to Hand shower
4-Port
Diverter
FROM HOT VALVE TO DIVERTER
FROM DIVERTER TO SPOUT
FROM COLD VALVE TO DIVERTER
Cold Valve
Hot Valve
LAYOUT OF COMPLETELY INSTALLED ROMAN TUB FILLER WITH HAND HELD SHOWER
Diverter
SANTEC
SANTEC
pull tab cap
3.
HAND HELD SHOWER TRIM INSTALLATION
A.
- Slip the flange though the hose and screw it onto the shower flange mount.
B.
- Take off the slip tab cap.
- Take off the rubber band with rubber and red washers.
MAKE SURE THAT THE HOSE DOES NOT FALL INTO THE FLANGE MOUNT.
-
Install the hand held shower unit with the rubber and red washers onto the hose.
C.
- Screw the handle trim onto the diverter's base ring.
Make sure the handle lever is aligned properly
4.
WATER TEST AND FLUSH THE LINE
PLEASE REFER TO 3150VF-TM INSTALLATION INSTRUCTION
- After all the connections have been made, remove the spout's aerator housing
basket and washer.
- Turn on the water on both hot and cold sides and flush the lines for 45 seconds.
- Turn off the water and reinsert the washer, basket and Housing.
- Turn on the water and check for leakages at all joints. If water leaks from any of
the connections tighten the connection until the leakage stops.
.
Rubber Washer
Red Washer
Diverter
SANTEC
SANTEC
Flange Mount
A
B
Diverter
SANTEC
SANTEC
C
3156ML-TM