beautypg.com

Installation instructions, Installation instruction – Santec 2529XA User Manual

Page 2

background image

INSTALLATION INSTRUCTIONS

FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION

.

AFTER FLUSHING , SHUT OFF BOTH SUPPLY LINES.

MINIMUM HOLE SIZE FOR THE HANDLE TRIMS IS 1 5/8” AND MAXIMUM OF 1 3/4”

INSTALLATION INSTRUCTION

INSTALLING THE VALVE WITHOUT THE TRIM

1- If the valve is installed first without the trim, please leave
3 1/8” to 3 ½” space between the center of the inlet and the
finished wall. This will leave enough thread length to be
adjusted when the trim is installed.

WARNING: Where tile construction is planned for the
finished walls, allow for the extra thickness
dimensions when roughing in the valves.

INSTALLING THE VALVE WITH THE TRIM

1- Install the valve onto the wall with 2” space
between the center of the valve inlet and the
finished wall.
Screw the handle flange with the flange washer
onto the handle bell and tighten it firmly.

2- Screw the handle bell, flange and washer onto
the all thread, press them firmly against the wall and
mark the position. Remove the handle bell, flange
and washer and cut off the excess thread.
Reinsert the handle bell, flange and washer onto
the all thread.

PAGE 02

2529XA _ _

center of IN port

FLANGE WASHER

finished wall

HANDLE FLANGE

HANDLE BELL

HANDLE

ALL THREAD

STEM

ALL THREAD

STEM

3

1/8

” ~ 3 ½