beautypg.com

Installation instructions, Installation instruction – Santec 2513YC User Manual

Page 2

background image

INSTALLATION INSTRUCTIONS

FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION

.

AFTER FLUSHING , SHUT OFF BOTH SUPPLY LINES.

MINIMUM HOLE SIZE FOR THE HANDLE TRIMS IS 1 5/8” AND MAXIMUM OF 1 3/4”

INSTALLATION INSTRUCTION

INSTALLING THE VALVE WITHOUT THE TRIM

1- If the valve is installed first without the trim, please leave
2” to 2-1/8” space between the center of the valve inlet
and the finished wall. This will leave enough thread length
to be adjusted when the trim is installed.

WARNING: Where tile construction is planned for the
finished walls, allow for the extra thickness
dimensions when roughing in the valves.

INSTALLING THE VALVE WITH THE TRIM

1- Install the valve onto the wall with 2” space
between the center of the valve inlet and the finished
wall.
Screw the handle flange with the flange washer
onto the handle bell and tighten it firmly.

2- Screw the handle bell, flange and washer onto the all
thread, press them firmly against the wall and mark
the position. Remove the handle bell, flange and washer
and cut off the excess thread.
Reinsert the handle bell, flange and washer onto the all
thread.

PAGE 02

2513YC _ _

center of IN port

FLANGE WASHER

finished wall

2” ~ 2

1/8

HANDLE FLANGE

HANDLE BELL

HANDLE

ALL THREAD

STEM

ALL THREAD

STEM