Installation instructions, Illustration c, Trim installation – Santec 2231LM User Manual
Page 3: Cold warm warmer hot
TRIM INSTALLATION
- Place the shower plate on the all thread.
- Screw the handle flange onto the handle bell and tighten it firmly.
- Screw the handle bell with handle flange, washer and adapter
onto the all thread and mark the position. Remove the handle bell
from the all thread and cut off the excess thread.
Reinsert the handle bell onto the all thread.
- Insert the handle onto the stem. Measure the excess between
the handle bell and the handle. Take off the handle and cut the
excess stem.
- Reinsert the handle onto the stem. Tighten the handle set screw
firmly using the Allen Key.
H
H
C
C
INSTALLATION INSTRUCTIONS
2231LM _ _
FLANGE WASHER HANDLE FLANGE HANDLE BELL
HANDLE
Stem
All Thread
Lock Nut
Lock Plate
Trim Plate
PAGE 03
COLD
WARM
WARMER
HOT
ILLUSTRATION C
PM-280 - SERVICE VALVE (OPTIONAL)
VALVE CARTRIDGE - TE010
MECHANICAL STOP- TE013
LIMIT STOP- TE014
PM-010 - STEM
TEFLON WASHER
PM-009 - LOCK PLATE
PM-012 - LOCK NUT
PM-011 - ALL THREAD
FILTER SCREEN
FLANGE ADAPTER