3
Vermont Castings Gas Patio Fire
GPF Dimensions
11
¹⁄₂
"
(292mm)
5"
(127mm)
12"
(305mm)
3
¹⁄₄
"(83mm)
16
¹⁄₄
"
(413mm)
11
³⁄₈
"
(289mm)
8
¹⁄₄
"
(210mm)
Burner
4237
Fig. 1 Physical dimensions.
Burner Assembly
Flex Line
Valve
Propane
Regulator/Hose
Natural
Gas Hose
FP1129
Fig. 2 GPF parts.
Gas Specifications
Max. Input
Model
Fuel
Btu/Hr
GPFMN
Natural Gas
75,000
GPFMP
Propane Gas
65,000
Gas Inlet Pressures
Natural
LP (Propane)
Minimum Inlet Pressure
5.5” w.c.
11.0” w.c.
Maximum Inlet Pressure
14.0”w.c.
14.0” w.c.
Minimum Clearance to Combustibles
Inches
mm
Floor
0
0
Side Walls
16
406
Top of unit to ceiling
7 ft.
2.1m