0 installation procedures – Sandia Aerospace SAFE 328 User Manual
Page 5
1.2.2 Operational Characteristics
Operating Voltage
22-31Vdc
Current
Operating
.400 Amps Nominal
Start-up .550
Amps
Air Flow (All Ports) 20 CFM No Static Pressure (10CFM @ .08 H2O Static Pressure)
Operating Temp
-20 to +55
o
C
Max Operating Altitude
55,000 Feet
1.2.3 Certification
FAA-PMA PQ0894SW Diamond DA40
DO 160D
[F1]BAA[S2R2U(F,B2,M)]XXXXXXZBAZA[XX]M[XXXX][XX]XX
2.0 Installation Procedures
2.1 General
The SAFE 328 is supplied with a mounting connector and four contacts. Only three contacts are re-
quired and the spare one is provided in case one is destroyed during installation. The SAFE 328 is
mounted with three (3) number 6 or 8 screws. Cooling air is ducted to the device to be cooled using
aircraft approved tubing. Unused ports should be capped.
2.2
Equipment Required
2.2.1 Supplied
SAFE 328 System Includes:
SAFE 328 Fan 305467-00
Installation
Kit 305477-00
Mating
Connector
305479-03
Mating
Pins
305478
2.2.1 Required but not supplied
Three (3) Number 6-32, 8-32 or equivalent mounting screws
2.3 Mounting
The SAFE 328 mounts with three (3) number 6-32 or 8-32 or equivalent machine screws.
4
305467-00-IS
Description
Manufacturer
Series Number
Manf. Part Number
Sandia Part Number
Connector Housing
Molex
2695
22-1-3037
305479-03
Crimp Contact
Molex
2759
08-50-0114
305478
Hand Crimper Tool
Molex
NA
*11-01-0185 or CR2262C
NA
Extraction Tool
Molex
NA
*11-03-0022
NA
Insertiion Tool
Molex
NA
*63812-0000
NA
Figure 2-1
Connector item Part Numbers