beautypg.com

Lighting and operating instructions, Odgsr series outdoor gas fireplace, For your safety read before lighting – Vermont Casting ODGSR42A User Manual

Page 11: Lighting instructions

background image

11

ODGSR Series Outdoor Gas Fireplace

20007114

3. Open control access panel.
4. Push in gas control knob slightly and turn

clockwise

to "OFF". Do not force.

5. Close control access panel.

1. STOP! Read the safety information above.
2. Turn OFF all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to

Step 4. For RN/RP appliances turn the On/Off
switch to “OFF” position or set thermostat to
lowest level.

4. Open control access panel.
5. Push in gas control knob slightly and turn

clockwise

to "OFF".

10. Push the control knob all the way in and hold.

Immediately light the pilot by repeatedly depress-
ing the piezo spark ignitor until a flame appears.
Continue to hold the control knob in for about one
(1) minute after the pilot is lit. Release knob and it
will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 8.

• If knob does not pop up when released, stop

FOR YOUR SAFETY READ BEFORE LIGHTING

• If you cannot reach your gas supplier, call the

Fire Department

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call
a qualified service technician. Applying force or
any attempted repair may result in a fire or explo-
sion.

D. Do not use this fireplace if any part has been

under water. Immediately call a qualified service
technician to inspect the heater and to replace
any part of the control system and any gas control
which has been under water.

A. This heater has a pilot which must be lit manu-

ally. When lighting the pilot follow these
instructions exactly.

B. BEFORE LIGHTING smell all around the

heater area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any fireplace
• Do not touch any electric switch
• Do not use any phone in your building
• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's
instructions.

To Turn Off Gas to Heater

Lighting and Operating Instructions

1. Turn the On/Off switch to "OFF" position or set

the thermostat to lowest setting.

2. Turn off all electric power to the fireplace if

service is to be performed.

Lighting Instructions

6. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor. If
you smell gas, STOP! Follow "B" in the safety
information above. If you do not smell gas, go
to the next step.

7. Remove glass door before lighting pilot. (See

Glass Frame Removal section).

8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise

to "PILOT".

and immediately call your service technician or
gas supplier.

• If after several tries, the pilot will not stay lit,

turn the gas control knob to "OFF" and call your
service technician or gas supplier.

11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the On/Off switch to

ON” position or set thermostat to desired setting.

14. Turn on all electrical power to the fireplace.

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

Euro SIT

SIT NOVA

Honeywell

PILOT

ON

OFF

ON

PILOT

O

FF

OFF

FP1067

lighting instruction

knobs

3/9/01 djt

5

4

3

2

1

OF

F

Pi

lot

3/8" - 1/2"

FP1068

Lighting instructions

Pilots

This manual is related to the following products: