2. Dissolve completely the contents of the single package of de-scaling powder

in 2 cups (0.5L) of water.

3. Pour the solution into the boiler.

4. Leave the solution in the boiler for one night with the filling cap off.

5. Completely empty the contents of the boiler and rinse three or four times

with water in order to eliminate possible residues of scale.

6. It is a good idea to spray the first steam onto a cloth and not directly on any

surface since there still may be scale in the system.

ATTENTION: IT IS NOT RECOMMENDED THAT yOU USE ANy OTHER CHEMICAL TO
CLEAN THIS PRODUCT. DOING SO WILL AUTOMATICALLy VOID THE WARRANTy.

ATTACHMENT COUPLINGS

If the attachment connections dry up after intensive use, put a small amount of
lubricant (Vaseline) around the O-rings on the male attachment.

TECHNICAL DESCRIPTION

120V Power

1750W

Cold water tank capacity

2L

Working pressure

4bar

Safety valve

Yes

REPLACEMENT & OPTIONS

#EA30N

Nylon brush

#EA30B

Brass brush

#EA30SS

Stainless steel brush (not supplied with steam cleaner)

#EACLOTH2

Replacement cloths (2/pack)

#JTPOWDER

Cleaning powder