Ram Trucks 2012 3500 - CNG Supplement User Manual
Page 29

WARNING!
• Do not attempt to force open or tamper with the
fuel fill receptacle. A sudden release of natural gas
may occur, possibly causing injury.
• Your vehicle fuel system has a maximum capacity
of 3600 pounds per square inch gauge (24.8 MPa)
compensated to a temperature of 70°F (21°C). Ex-
ceeding the fuel system capacity may result in fuel
system damage and possibly cause injury.
• Your vehicle should not be fueled if damage to the
container has occurred. The damaged container
should be retested and inspected as per the Main-
tenance section prior to be being placed back into
service.
NOTE:
The fuel containers must be visually inspected
every 36 months or 36,000 miles whichever comes first,
1 — NVG 1 Receptacle
2 — Fuel Filling Receptacle
4
STARTING AND OPERATING
27