TROUBLESHOOTING
Symptom
Cause
Corrective Action
No green LED when 
Connected to battery. 
The charger does not see 
the battery. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Both the green and red 
LED do come on, but 
the ammeter stays at 0. 
 
 
 
 
 
 
 
 
Break in DC cord, or 
connector. 
 
Battery voltage too low 
to turn the charger on. 
 
 
 
 
 
 
 
 
 
 
 
 
Battery is sulfated, and 
will not accept a charge. 
 
 
Have a qualified person 
make repair. 
 
If the battery has too 
low a voltage you may 
need to “jump” the dead 
battery with a charged 
battery, connecting 
positive to positive, and 
negative to negative so 
the charger has enough 
voltage to turn on. Once 
charging, and given time 
to build the voltage, the 
jumper battery can be 
disconnected. 
 
Leave the charger 
connected and ON. Over 
some hours, the 
ammeter may begin to 
rise indicating current 
flow. The amps will 
build to the full capacity 
of the charger, then 
work back to 0 
 
NOTE: Batteries in this 
condition may not be 
recoverable. 
When switched on, the 
red LED does not light, 
and no amps read on 
meter 
The panel mount fuse is 
blown. 
 
There is no AC power 
present at the plug. 
Replace with one having 
the same rating. 
 
Check that there is 
power at the source. If 
using an extension cord, 
check that it is not 
damaged. 