beautypg.com

2 technical specifications, Can ices-3(a)/nmb-3(a) – NORAC 54VT-IV-SP01 User Manual

Page 5

background image



3

2 Technical Specifications

CAN ICES-3(A)/NMB-3(A)

This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause

harmful interference in which case the user will be required to correct the interference at their
own expense.

This Class A digital apparatus complies with Canadian ICES-003.

Pursuant to EMC Directive – Article 9, this product is not intended for residential use.

Table 1: System Specifications

Supply Voltage (rated)

12VDC

Supply Current (rated)

10A

Hydraulic Pressure (MAXimum)

3300 psi

Baud Rate

250 kbps

Clock Frequency (MAXimum)

96 MHz

Solenoid Valve PWM Frequency

300 Hz

Ultrasonic Sensor Transmit Frequency 50 kHz
Operating Temperature Range

0°C to 80°C