10 Hydraulic Installation
Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.
Component failure due to oil contamination is not covered under the NORAC UC5
system warranty. It is recommended that a qualified technician perform the
hydraulic installation.
10.1 Valve Assembly
1. On a clean surface remove the plastic plugs from the block.
2. Install the 6MB-6MOR (F05) fittings into the “P” and “T” ports. Tighten to 18 ft-lbs (24
Nm).
3. Install the 4MB-4MOR (F06) fitting into the “S” port. Tighten to 11 ft-lbs (15 Nm).
4. Install the 6MB-6MOR (F05) fittings into the “A” and “B” ports. Tighten to 18 ft-lbs (24
Nm).
5. Orifices are not installed in the NORAC valve block for this sprayer since the John Deere
orifices in the wing cylinders are used.
Figure 23: NORAC Valve Block Details