background image



16

7.2 Roll Sensor Mounting Guidelines: Trapeze-Suspended Booms

1. When mounting the roll sensors, mount one to the trapeze link (boom frame) and one to

the trapeze support (chassis). For optimal performance, minimize the distance from the

boom frame roll sensor to the pivot point (A) and minimize the vertical distance between
the chassis roll sensor and the pivot point (B).

Figure 16: Roll Sensor Mounting on a Trapeze Suspended Boom

2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.

3. Both roll sensor cables MUST be pointing towards the right hand wing of the sprayer.

4. Ensure both roll sensors are mounted adequately and that the cables provide enough slack

to allow sufficient boom roll.

Connectors towards
Right-hand Wing 