4 installation procedure, 1 sensor installation – NORAC 4465BC+LP User Manual
Page 8
5
4
INSTALLATION PROCEDURE
4.1 S
ENSOR
I
NSTALLATION
1. Mount the Low Profile Sensor Mounting
Brackets (B20) onto the boom as show in
Figure 3 and Figure 4 with the mounting
base in front of the tube.
Figure 3: Low Profile Bracket Mounting
Figure 4: Low Profile Bracket Mounted on
Boom
2. Mount the sensor brackets onto the boom
half way between the tip and center of the
sprayer (Figure 7).
If possible, mount the sensor
brackets while the booms are in their
folded position to ensure that they
will not interfere with anything when
the boom is folded for transport.
3. Mount the NORAC UC4+ ultrasonic
sensors (E02) into the sensor brackets. The
sensors should be oriented forward (ahead)
of the boom.
When installing the UC4+ sensors
(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial
number on the right hand side
(Figure 7).
4. Sensor cables should run through the
mounting bracket hole and then behind the
bracket. Cable-tie the connector in place.
The cable must not hang below the boom.
Front