4 installation procedure, 1 sensor installation – NORAC 4465BC+NT User Manual
Page 8
5
4
INSTALLATION PROCEDURE
4.1 S
ENSOR
I
NSTALLATION
1. Assemble the Breakaway Sensor Mounting
Brackets (B19) as show in Figure 3.
Figure 3: Breakaway Sensor Bracket
Exploded View
2. Mount the sensor brackets onto the boom
half way between the tip and center of the
sprayer (Figure 7).
If possible, mount the sensor
brackets while the booms are in their
folded position to ensure that they
will not interfere with anything when
the boom is folded for transport.
3. Mount the NORAC UC4+ ultrasonic sensor
(E02) into the sensor brackets. The sensors
should be oriented forward (ahead) of the
boom (see Figure 4 and Figure 6).
When installing the UC4+ sensors
(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial
number on the right hand side
(Figure 7).
Figure 4: An Acceptable Mounting
4. Sensor cables should run through the
mounting bracket tube and then behind the
member the bracket is mounted onto.
Cable-tie the connector in place. The cable
must not be allowed to hang below the
boom (Figure 5).
Figure 5: Sensor Cable Routing
Avoid mounting sensors in locations
where they may read from parts of
the boom.
FRONT