3 calibrating the slant valve – NORAC UC4+BC+HD5 Part 2 User Manual
Page 8
5
5.3
Calibrating the Slant Valve
The roll (slant) valve can only be calibrated manually as described below. When calibrating the
roll valve you must first calibrate the deadzone clockwise and counter clockwise settings and
then the gain clockwise and counter clockwise settings.
Navigating to the Slant Valve Settings:
1. Ensure the UC4+ control panel is in manual mode, at the run screen.
2. Toggle "SETUP" until the display shows "More?". Toggle "AUTO (YES)" to confirm.
3. Toggle "SETUP" until the display shows "Roll?". Toggle the "AUTO (YES)" switch to
confirm.
4. Toggle the "SETUP" switch to access the next menu prompt or toggle "SENSOR DISPLAY"
to access the previous menu. Choose the dead zone up/down or gain up/down setting
(Figure 3).
Roll Channel On
Roll Channel Dead Zone Clockwise (cw)
Roll Channel Gain Clockwise (cw)
Roll Channel Dead Zone Counter Clockwise (ccw)
Roll Channel Gain Counter Clockwise (ccw)
Figure 3: Slant Valve Settings
KP
5
KP
5
Roll OnU
DZ 20
DZ 20
Sensor
Display
Setup