beautypg.com

NORAC UC4.5-BC-VS1 User Manual

Page 17

background image



14

6.2 Roll Sensor Mounting Guidelines: Center Pivot Booms

1. When mounting the roll sensors, mount the roll sensor without the temperature probe on

the boom frame and the roll sensor with the temperature probe on the chassis (non-

pivoting portion of the sprayer). For optimal performance, minimize the distance between
the roll sensors (A) and minimize the height from each roll sensor to the pivot point (B).

Figure 13: Roll Sensor Mounting on a Center Pivot Suspended Boom

2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.

3. Both roll sensor cables should be pointing towards the right hand wing of the sprayer.

4. Ensure both roll sensors are mounted adequately and that the cables provide enough slack

to allow sufficient boom roll.

5. The chassis roll sensor can also be mounted inverted to minimize the distance between the

roll sensors (Figure 14).

Figure 14: Inverted Chassis Roll Sensor Mounting on a Center Pivot Suspended Boom