NORAC UC4.5-BC-FC1 User Manual
Page 19
16
5. Connect two sets of tees on C10 in-line with the Flexi-Coil joystick cable at the hitch
connections. One of the receptacles on the tees will be marked “Sprayer”. This connector
is to be connected to the Flexi-Coil plug that comes from the sprayer side. Plug the other
connections together.
6. Connect C04 to the 6-pin tower on C10.
The valve extension cable (C04) may be packaged with one GP end not
installed. This is normal; it helps installations for other sprayer types. Pin this
connector on (connector included) as per drawing in Section 10. TAKE
EXTRA CARE! These pins require a special tool to remove if an error is
made.
7. Route C04 and C06 from the hitch to the rear of the sprayer to the area where the
NORAC hydraulic valves are located.
8. Connect the 6-pin tower on C03 to C04. Connect the 2-pin connectors on C03 to the
NORAC valve block, as shown in Figure 17.
9. The connectors on the valve cable (C03) are marked RIGHT UP, LEFT UP, RIGHT
DOWN and LEFT DOWN. Cables labeled with UP go on the same side as the
hydraulic hoses.
Figure 17: Valve Cable Connections
10. Fasten the 8-way coupler to the boom with cable ties. Connect C06 to the 8-way coupler.
11. Connect both roll sensors to the 8-way coupler.