Maximum ratings, Operating range, Electrical characteristics – Cypress CY7C1250V18 User Manual
Page 20: Dc electrical characteristics, Ac input requirements
CY7C1246V18, CY7C1257V18
CY7C1248V18, CY7C1250V18
Document Number: 001-06348 Rev. *D
Page 20 of 27
Maximum Ratings
Exceeding maximum ratings may impair the useful life of the
device. These user guidelines are not tested.
Storage Temperature ................................ –65°C to + 150°C
Ambient Temperature with Power Applied. –55°C to + 125°C
Supply Voltage on V
DD
Relative to GND .......–0.5V to + 2.9V
Supply Voltage on V
DDQ
Relative to GND ..... –0.5V to + V
DD
DC Applied to Outputs in High-Z ......... –0.5V to V
DDQ
+ 0.3V
DC Input Voltage
............................... –0.5V to V
DD
+ 0.3V
Current into Outputs (LOW)......................................... 20 mA
Static Discharge Voltage (MIL-STD-883, M 3015).... >2001V
Latch up Current..................................................... >200 mA
Operating Range
Range
Ambient
Temperature
V
DD
V
DDQ
Com’l
0°C to +70°C
1.8 ± 0.1V
1.4V to V
DD
Ind’l
–40°C to +85°C
Electrical Characteristics
Over the Operating Range
DC Electrical Characteristics
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
DD
Power Supply Voltage
1.7
1.8
1.9
V
V
DDQ
IO Supply Voltage
1.4
1.5
V
DD
V
V
OH
Output HIGH Voltage
V
DDQ
/2 – 0.12
V
DDQ
/2 + 0.12
V
V
OL
Output LOW Voltage
V
DDQ
/2 – 0.12
V
DDQ
/2 + 0.12
V
V
OH(LOW)
Output HIGH Voltage
I
OH
= –0.1 mA, Nominal Impedance
V
DDQ
– 0.2
V
DDQ
V
V
OL(LOW)
Output LOW Voltage
I
OL
= 0.1 mA, Nominal Impedance
V
SS
0.2
V
V
IH
Input HIGH Voltage
V
REF
+ 0.1
V
DDQ
+ 0.15
V
V
IL
Input LOW Voltage
–0.15
V
REF
– 0.1
V
I
X
Input Leakage Current
GND
≤ V
I
≤ V
DDQ
–2
2
μA
I
OZ
Output Leakage Current
GND
≤ V
I
≤ V
DDQ,
Output Disabled
–2
2
μA
V
REF
Input Reference Voltage
Typical Value = 0.75V
0.68
0.75
0.95
V
I
DD
V
DD
Operating Supply
V
DD
= Max., I
OUT
= 0 mA,
f = f
MAX
= 1/t
CYC
300 MHz
1000
mA
333 MHz
1080
mA
375 MHz
1210
mA
I
SB1
Automatic Power Down
Current
Max. V
DD
,
Both Ports Deselected,
V
IN
≥ V
IH
or V
IN
≤ V
IL
f = f
MAX
= 1/t
CYC
,
Inputs Static
300 MHz
290
mA
333 MHz
300
mA
375 MHz
320
mA
AC Input Requirements
Over the Operating Range
Parameter
Description
Test Conditions
Min
Typ.
Max
Unit
V
IH
Input HIGH Voltage
V
REF
+ 0.2
–
V
DDQ
+ 0.24
V
V
IL
Input LOW Voltage
–0.24
–
V
REF
– 0.2
V
Notes
15. Power up: assumes a linear ramp from 0V to V
DD
(min) within 200 ms. During this time V
IH
< V
DD
and V
DDQ
< V
DD
.
16. Outputs are impedance controlled. I
OH
= –(V
DDQ
/2)/(RQ/5) for values of 175
Ω < RQ < 350Ω.
17. Outputs are impedance controlled. I
OL
= (V
DDQ
/2)/(RQ/5) for values of 175
Ω < RQ < 350Ω.
18. V
REF
(min) = 0.68V or 0.46V
DDQ
, whichever is larger. V
REF
(max) = 0.95V or 0.54V
DDQ
, whichever is smaller.
19. The operation current is calculated with 50% read cycle and 50% write cycle.