break-in period

Breaking-in the engine will help

1.

to ensure proper equipment and

engine operation, and will extend

the engine’s lifespan. The warranty

is void if the engine is not broken

in properly. The first 20 hours of

operation is the break-in period.
During the first 3 hours of use:

2.

Do not apply a heavy load to the

equipment.

After the first 20 hours of use:

3.

Change the engine oil.


Under normal operating conditions

subsequent maintenance follows

the schedule explained in the

MAINTENANCE AND SERVICING

section.

Equipment operation

To pREvEnT

sERious injuRY

AnD DEATh:

Do noT connEcT

gEnERAToR DiREcTlY To

housEholD WiRing.

A portable electric generator

that is connected to your

household wiring without a

proper cut off switch can

‘back feed’ into the power

lines connected to your home.

power created by your

generator can injure or even

kill a utility lineman making

outage repairs many miles

away.

Only a certified electrician can

safely connect the generator

to your home’s wiring.

Make sure your generator is properly

1.

grounded to avoid electrical shocks.

Connect a 10 gauge or larger

insulated copper wire to the Ground

Connection on the Control Panel.

Connect this wire to a suitable

external ground, such as a metal

stake in the ground.
Don’t overload the generator. The

2.

total wattage used by the appliances

should be less than the output rating

of the generator. If you put too many

appliances on the generator, it could

seriously damage the appliances

and electronics. Overloading the

generator could also cause fires in

the power cord. This generator is

rated at 3000 / 3500 Watts.

note: At start-up, appliances draw more

power in a surge than they do during

continuous operation. When figur-

ing total wattage of all appliances

connected to this generator, use the

higher start-up amperage rating of

each appliance.
Do not exceed the current limit

3.

specified for any one receptacle.
Move the AC Circuit Breaker switch

4.

to the ON position.
Plug in your extension cord or

5.

appliance.
Be sure that all appliances are in

6.

good working order before connecting

them to the generator. If an appliance

begins to operate abnormally,

becomes sluggish, or stops suddenly,

turn off the AC Circuit Breaker and

the generator Engine Power Switch

immediately. Then disconnect the

appliance and examine it for signs of

malfunction.