beautypg.com

CFM Corporation HEF26 User Manual

Page 9

background image

9

Remove Screws

Fig. 6 Remove screws that hold refractory bracket with
ember bed.

5. Remove those two (2) screws using an appropriate

screwdriver. One screw is located on either side of
the unit.

10008388

Depending on your model, the fireplace uses two (2) or
three (3) clear 120 Volt, 60 Watt, E-12 socket base
light bulbs (small base, chandelier candle type) located
under the ember bed. Units with overhead lights (Fig.
9) use two (2) clear 120 Volt, 5 Watt, E-12 socket base
light bulbs (small base, chandelier candle type) located
above the logs. For convenience, if one of the light
bulbs burns out, it may be easier to replace all of the
light bulbs at the same time.

Do not exceed 60 Watts per bulb for the
ember bed bulbs and 5 Watts per bulb for
the overhead lights. Use of higher rated
bulbs may result in a fire, causing proper-
ty damage, personal injury or loss of life.

1. Turn off power to the unit.

2. Let fireplace cool if it has been operating.

3. Remove fixed front panel, or open doors (depend-

ing on model).

4. Locate two (2) screws that hold the refractory (brick

patterned) bracket together with the ember bed.
(Fig. 6) (Not applicable to HEF22)

Replacing the Light Bulbs

Pull Here (both sides)

Fig. 7 Pull ember bed out of unit.

6. Pull the ember bed out of the unit, by gently pulling

towards you and only slightly upwards. Depending
on the model, you can remove the refractory prior
to removing the ember bed.

7. Looking into the opening of the unit under the

ember bed, visually locate the light bulbs.

8. Remove the light bulbs by unscrewing them out of

the bases, turning them counterclockwise. You can
use one hand to hold the light socket in place, if
required.

60 W Light Bulbs

Fig. 8 Remove and replace light 60 W bulb(s).

9. Install the new light bulb(s) by turning the light bulb

into the base clockwise. You can use one hand to
hold the light socket in place, if required.

10.Reposition the ember bed. If required, gently raise

the refractory panels, one at a time, to tuck the
ember bed edge underneath them.

11.Reposition the refractory bracket, aligning the

refractory in place as required.

12.Reinstall the two (2) screws removed in Step 5.

5 W Light Bulb

Fig. 9 Remove and replace 5 W bulb(s).

This manual is related to the following products: