beautypg.com

Leslie Controls AEROFLOW SUPPLEMENT Special Up-seating Flow to Open Mini-P User Manual

Leslie Controls Equipment

background image

12501 Telecom Drive, Tampa Florida 33637

Installation, Operating and

Maintenance Instructions

Supplement

10/2.5.1.D

Rev. 0

AEROFLOW SUPPLEMENT

Special Up-seating Flow to Open Mini-P


TABLE OF CONTENTS

INSTALLATION ......................................................................................................................................... 1

MAINTENANCE ......................................................................................................................................... 1

ILLUSTRATION INDEX

F

IGURE

1

-

S

PECIAL

U

PSEATING

FTO

M

INI

-P ............................................................................................. 2


INSTALLATION







NOTE: Refer to Fig. 1 for installation.

1.

Install seat gasket (504b) into valve body (306).


2.

Install valve plug (502) into cage liner (600) and
install roll pin (505) as shown.


3.

Install valve plug (502) and cage liner (600) into
valve body (306).


4.

Install gasket (504a), seat (503) and bonnet gasket
(305).


5.

Complete the bonnet (302) installation as stated in
the valve IOM.



MAINTENANCE

1.

During routine maintenance check the seating surface
of the valve plug seat (503) and the plug (502).
Replace/Repair as needed.


2.

To replace the valve plug (502), tap out the roll pin
(505), and replace with new.


3.

The valve IOM should be followed for all operating
and maintenance procedures.

CAUTION!

All warnings from valve IOM must be followed.