Kuzma Cartridge set up User Manual
Page 2
Fig. 15 Alignment at B
8. If the cantilever is not in alignment then rotate protractor until it is in alignment somewhere along
the line “x-y” though stylus will probably not be at zero point B. Raise the cueing device a bit for
better viewing. (Fig.15)
9. If stylus is in front of point B, pull the cartridge forward (along side) in the slots of the headshell for
approximately the same distance “S” as stylus is overhanging zero point B. If it is behind point B,
push cartridge backwards towards the pivots of the tonearm for distance “S” (Fig. 16)
Fig.16 Stylus tip is in front of zero point B.
10. Now rotate protractor and again position stylus at zero point A as described in 5 and 6
above, ensuring that the position of the cartridge in the slots alongside is not changed but only rotated
for alignment of the cantilever in zero point A. (Fig.17)
Fig.17 Rotation at A
“S”
B
“S”
0%