10. Now rotate protractor and again position stylus at zero point A as described in 5 and 6 
above, ensuring that the position of the cartridge in the slots alongside is not changed but only 
rotated for alignment of the cantilever in zero point A. (Fig.17) 
Fig.17 Rotation at A 
 
11. Recheck alignment of the cantilever at zero point B. If cantilever is not aligned here, 
rotate protractor to find where on line “x- y” the cantilever is aligned again. (Fig.18&15) 
Fig. 18 Alongside line “X-Y” alignment at B 
 
If the stylus is still in front of zero point B on the line “x-y” as before, but nearer to point B, 
then again pull cartridge slightly forward for distance “S” and repeat the whole process by 
aligning at zero point A until the stylus will be at zero point B. 
If stylus end up behind the zero point B on line “x-y” then move cartridge in opposite 
direction to before, backwards and realign it at zero point A. 
If stylus is still behind the B point, the cartridge should be pushed back and realign at zero 
point A and realigned again at zero point B. 
12. Continue until the stylus is in alignment at both points. 
 
REMEMBER STEPS: 
a) Put stylus at zero point A and by rotation align cantilever along XY line. 
b) Align cantilever along XY line at zero point B by rotating protractor and see where stylus 
is on the line XY- in front or behind zero point B. 
c) Move cartridge along (not rotating it) for the same distance as stylus is overhanging zero 
point B for the same distance to increase the overhang. 
d) Repeating these steps (a,b,c,a,b,c,…) will ensure that stylus& cantilever are in alignment at 
both zero points A&B. 
 
NOTE: Ensure that cantilever is not twisted due to bias force. 