Application Note

Doors32

2.0

Wiring an Elevator Control System

For elevator control there are four reader to PXL-250 controller wiring connections that must be
made. Figure 1 provides a wiring diagram of an elevator control system.

1. The reader antenna line must be daisy-chained to all controller antenna inputs (Pin 1 of TB-5 or

TB-6 on the controllers).

2. The reader ground line must be daisy-chained to all controller antenna grounds to provide a

standard ground reference for all controllers (Pin 4 of TB-5 or TB-6 on the controllers).

3. The reader shield line must be connected to the A-door controller antenna ground at the master

controller (Pin 4 of TB-5 on the master controller).

4. The power line must be connected to the master controller only (Pin 3 of TB-5 on the master

controller).