beautypg.com

Dutchwest, Fireplace installations - through the fireplace, Wall pass-throughs – CFM Corporation 2462 User Manual

Page 8

background image

8

Dutchwest

7001135

Fireplace Installations -

Through the Fireplace

The Convection heaters may be installed either without
legs* as a fireplace insert, or with standard legs at-
tached - depending on the safety regulations that apply
to your situation, the height of the fireplace opening and
your own preference. For either situation, the chimney
connector/positive connection kit extends back from the
stove, enters the fireplace cavity, and turns upward. It
then passes through the fireplace damper opening and
smoke chamber and connects to the chimney flue.
In such installations, a “positive connection” must be
made to the chimney flue with a special kit available
from your local dealer. Also, special clearance and floor
protection provisions must be observed. These provi-
sions are discussed in the Clearance and Floor Protec-
tion sections respectively.

Wall Pass-Throughs

Whenever possible, design your installation so the con-
nector does not pass through a combustible wall. If you
must use a wall pass-through in your installation, check
with your building inspector before you begin and con-
struct it in accordance with local building codes. Also
check with the chimney connector manufacturer for any
specific requirements.
Accessories are available for use as wall pass-
throughs. If using one of these, make sure it has been
tested and listed for use as a wall pass-through.
All combustible material in the wall is cut away a suffi-
cient distance from the single-wall connector to provide
the required 12” (305 mm) clearance for the connector.
Any material used to close up the opening must be non-
combustible.
The following wall pass-through methods may be ap-
proved in your area:

Use a section of listed factory-built chimney with a
nine-inch clearance to combustibles.

Place a chimney connector pipe inside a ventilated
thimble, which is then separated from combustibles
by six inches (152 mm) of fiberglass insulating mate-
rial.

If the stove is installed without legs, we recommend
the use of noncombustible tiles or pavers as shims
to allow air flow into the convection air inlets under
the stove. Make sure not to block air slots instove
bottom with shims or remove fan cover.

Place a chimney connector pipe inside a section of
listed solid-insulated, factory-built chimney, with an
inside diameter 2 inches (51 mm) larger than the

chimney connector and having 1 inch (25.4 mm) or
more of insulation and maintaining a minimum 2 inch
air space between the outer wall of the chimney and
combustibles.

In Canada: The Canadian Standards Association has
established different guidelines. Figure 11 shows one
method, in which all combustible material in the wall is
cut away to provide the required 18” (450 mm) clear-
ance for the connector. The resulting space must
remain empty.

DO NOT CONNECT THE HEATER TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.

ST421

hollow

wall pass through

with noncombust

6/27/00 djt

18”

(450mm)

Empty Space

All Around

the Chimney

Connector

Sheet Metal

Cover

(One side

only)

ST421

Fig. 11 Hollow wall pass-through.

ST420

wall pass through

with noncombust

6/27/00 djt

Chimney Con-

nector

12”

(305mm)

12”

(305mm)

ST420

Fig. 10 Wall pass-through enclosed with noncombustible
materials.

This manual is related to the following products: