beautypg.com

Troubleshooting, Co.,ltd, Checking the problem first – CatEye EC-8OOOU User Manual

Page 12: Limited warranty, Specifications

background image

Copyright© 1996 Cateye Co., Ltd.

Printed in Japan ECME80U-9807220

0689027

1

CO.,LTD.

Troubleshooting

1

Checking the problem first

Before suspecting the failure of the unit, check the fol-
lowing point:

No display on screen at all.
Display is unusual.

Check if the batteries have run short.
Replace all of four batteries with brand-new ones.

Beep would not stop.

Have you set your age correctly?
Setting of age will automatically set the upper pulse
limit. Set your correct age.

The progress to target has been reached quickly.

Have you set the target time or target calorie?
Set the values in accordance with your exercise pro-
gram.

No display of heart rate on screen

Have you set the earlobe sensor of pulse sensor cor-
rectly?
Set the sensor at the center of your earlobe.
The sensor should be set after removing earrings
Is the pulse sensor plug firmly connected?
Insert the plug correctly.
Has the pulse sensor been damaged?
Check the pulse sensor according to the check proce-
dure.
If it is found damaged, replace it with a brand-new one.

Unusually high heart rate is displayed.

Check the pulse sensor according to the check proce-
dure.
If it is found damaged, replace it with a brand-new one.

2

Limited warranty

Cat Eye Co., Ltd. guarantees that the Cateye Ergociser
Model EC-8000 is free from material defects and malfunc-
tions, for a period specified in the separate Warranty Card.
In case there should be defects or malfunctions under cor-
rect and normal personal use, Cat Eye will repair or re-
place the unit or parts, according to the terms and condi-
tions mentioned in the Warranty Card.

If repair service is required, contact the dealer where you
purchased the unit.

The warranty covers only the main resistance unit and the
control panel. Accessories such as pulse sensor, and me-
chanically consumable parts are not covered.

Specifications

Load:

Eddy current system utilizing permanent magnet

Load adjustment: 8-step adjustment by using manual lever

Load range:

approx. 10 - 240 watts (subject to pedal cadence)

Acceleration:

2-step acceleration by using a V-rib belt

Control system:

4-bit microcomputer

Display:

LCD

Display function:

Function

Range

Accuracy

Heart rate

50-220 /min

±

1bpm (stable state)

Cadence

40-80 rpm

9-step graph

Elapsed time

0min00sec-99min59sec

±

0.003%

Work rate

0-999 watts

±

5watts at 50watts

Calorie consumption 0-999 kcal

Estimated value

Progress to target

remaining 8/8-0/8

8-segment graph

Pedal resistance

1-8 levels

8-segment graph

Screen display

Display in input screen or exercise screen

Heart mark

Blinks to heart rate

Battery mark

Illuminates when batteries run short

Error mark

Illuminates when fails to detect the pulse sen-

sor signal

Pulse sensor OK mark Illuminates at the time of pulse sensor test

Setting function

Age

10-99 years of age (initial value: 40)

Target time

0-99 min. (initial value 20)

Target calorie

0-999kcal (initial value 0)

*Either of target time or target calorie can be set.

Upper pulse limit

Automatically set (200–age) by inputting the

value for age.

*Setting can be changed by operating a button.

Alarm function

Upper pulse limit alarm:

Beep sound when the heart rate exceeds

preset upper pulse limit

Target achievement alarm: Beep sound when the target time or tar-

get calorie setting has been reached.

Power supply:

AA(R6) x 4

Battery life:

Approx. 200 hours (by alkaline batteries)

User's weight limit: 286 lbs (130 kg)

Measurement:

22-1/16 x 51-31/32 x 39-25/32” max

(560 x 1320 x 1010 mm)

Weight:

approx. 68 lbs (31 kg)

*Specifications and design subject to change without notice.

2-8-25, Kuwazu, Higashi Sumiyoshi-ku, OSAKA, 546-0041 JAPAN
PHONE: 81-6-719-7781
FAX:

81-6-719-2362

Made in Japan